Off-grid microgrid: Integrated Solar, Energy Storage, And Diesel Generation System

1. Background on the Demand for Off-Grid Microgrids using Integrated Solar, Storage, and Diesel Systems

In modern construction sites, energy supply often faces significant challenges, especially when projects are located in remote areas far from existing power grids, leading to difficult and unstable electricity supply. Moreover, the power demand at construction sites is usually temporary, particularly in infrastructure projects such as roads, bridges, and tunnels. Once the project is completed, the need for large-scale power supply in the area significantly diminishes. Meanwhile, with the increasing global awareness of environmental protection, there is a growing demand to reduce the use of fossil fuels at construction sites, especially in nature reserves or other environmentally sensitive areas.

To address these challenges, the integrated solar, storage, and diesel power generation system (referred to as the “solar-storage-diesel integrated system”) has emerged. This system combines solar power generation, energy storage technology, and diesel generators to form an efficient and reliable energy supply system, particularly suitable for construction and emergency rescue scenarios requiring temporary power sources. This innovative solution is particularly advantageous in large-scale infrastructure projects, especially in geographically remote locations with long construction cycles, such as road, bridge, and tunnel construction. The solar-storage-diesel integrated system not only effectively supplements the shortcomings of the main grid but also significantly reduces fuel consumption by diesel generators. Additionally, in scenarios requiring rapid deployment of power systems, such as emergency rescue or temporary shelters, the system can provide reliable power support to meet basic needs such as lighting, communication, and medical care.

The solar-storage-diesel integrated system offers several advantages. First, as a clean and renewable energy source, solar photovoltaic power generation helps reduce carbon emissions and environmental pollution. Second, energy storage systems (such as lithium iron phosphate batteries) can effectively store excess solar power generated during the day for use at night or during cloudy days, ensuring a continuous and stable power supply. Additionally, diesel generators serve as backup power sources, providing necessary power support during extreme weather conditions or when the energy storage system is insufficient, thus ensuring the continuity of power supply. The system’s significant mobility and reusability allow it to respond to various emergencies and temporary needs flexibly.

The solar-storage-diesel system is designed based on the concept of the energy internet, integrating distributed photovoltaic and energy storage systems. It employs a hybrid AC/DC three-bus architecture, combining distributed power sources, digital intelligent distribution networks, layered energy storage devices, and short-term grid-connected/off-grid technology. Through a microgrid solar-storage integrated cabinet, the system achieves a reliable and stable temporary power supply. Using domestically developed secure and trustworthy wireless data buses and digital twin technology, the system enables digital operation and management of all temporary power points, providing a stable, uninterrupted power supply to the loads.

Given the cyclical nature of photovoltaic power generation, this system can store excess solar energy or use the main grid to charge batteries. When photovoltaic generation is unavailable, the system releases stored energy to balance the power demand of temporary buildings, reducing reliance on the main grid. In the event of a grid outage or failure, the energy storage battery can respond within less than 1 millisecond to provide power to critical loads.

When used as a temporary power source for construction sites, the solar-storage-diesel microgrid system can not only take advantage of peak-valley electricity price differences but also work with distributed photovoltaic power generation to achieve dynamic regulation of building electricity consumption. This not only effectively reduces energy consumption and decreases the frequency of diesel generator use but also allows participation in the electricity market, potentially becoming part of a virtual power plant, thereby generating additional economic benefits. The compact design of the solar-storage microgrid equipment, along with easy installation and transportation, makes it particularly suitable for construction projects requiring frequent relocation. Furthermore, with a lifespan of up to 25 years for photovoltaic panels, even in short-term temporary power scenarios, these characteristics favor the system’s reuse and redeployment.

In summary, the solar-storage-diesel integrated system not only meets the power needs of construction sites but also promotes sustainable development. The system has broad application prospects and is likely to become an important trend in the construction industry and emergency response fields in the future.

Integrated Solar, Energy Storage, And Diesel Generation Systems

2. Classification of Off-Grid Microgrids using Solar-Storage-Diesel Systems

The Asian Development Bank has categorized off-grid microgrids into three types: TYPE A, TYPE B, and TYPE C; this classification is primarily based on the penetration rate of renewable energy. TYPE A microgrids have the lowest renewable energy penetration, while TYPE C microgrids have the highest.

TYPE A Microgrid
Composed of diesel generators and photovoltaic systems, with diesel generators as the main power source. Since diesel generators need to run continuously and cannot operate at low power for long periods, and to ensure grid stability, this type of microgrid has a relatively low renewable energy penetration rate.

TYPE B Microgrid
This system includes solar, storage, and diesel power, with diesel generators as the main power source. Compared to TYPE A, the addition of an energy storage system allows for an increase in the capacity of the photovoltaic system. The storage system ensures grid stability and can store excess solar energy, resulting in a higher renewable energy penetration rate for this type of microgrid. However, the cost and return on investment are lower than TYPE A.

TYPE C Microgrid
This system includes solar, storage, and diesel power, with the energy storage system as the main power source and diesel generators as backup. Since the diesel generator is only used as a backup, this type of microgrid can achieve a renewable energy penetration rate of up to 100%. However, the storage system needs to be relatively large, and due to the high cost of energy storage systems, the return on investment for this type of microgrid is relatively low. This type of project is typically located in remote or hard-to-reach areas, such as islands.

3. Significant Advantages of the Off-Grid Solar-Storage-Diesel Microgrid in Temporary Power Applications

(1) Flexibility and Self-Sufficiency
The solar-storage-diesel integrated system can meet the power needs of various scenarios, providing a stable and reliable power supply for homes, commercial sites, and public facilities. Particularly in remote, off-grid areas, the system combines solar power, energy storage, diesel generators, and charging stations to offer portable power solutions to users. This flexibility allows the system to function effectively in different application environments, whether in fixed installations or scenarios requiring frequent relocation.

(2) Enhanced Power Supply Reliability
The solar-storage-diesel integrated system leverages solar power generation and energy storage to supply clean, renewable energy, while also equipping a diesel generator as a backup to ensure that power needs are met even in extreme situations. This multi-layered guarantee significantly enhances the reliability of the power supply, which is especially critical in areas where the power supply is unstable or where the grid is difficult to reach.

(3) Environmental Friendliness
The solar-storage-diesel integrated system effectively reduces the use of fossil fuels, thereby lowering environmental pollution. The system promotes the use of clean energy, aligning with the global trend toward a green, low-carbon energy transition. Reducing carbon emissions not only contributes to environmental protection but also helps companies comply with increasingly stringent environmental regulations, enhancing their social reputation.

(4) Economic Benefits
By reducing dependence on traditional power grids and lowering energy costs, the solar-storage-diesel integrated system provides users with significant economic benefits. This is particularly evident in remote areas, where reducing diesel usage not only cuts direct fuel costs but also reduces transportation and maintenance expenses. Additionally, users can generate extra income by participating in electricity market transactions or demand response programs.

(5) Technical Integration
The solar-storage-diesel integrated system features a modular design, allowing it to be configured with different capacities of energy storage devices based on customer needs. The system’s microgrid energy hub can directly connect photovoltaic modules, batteries, the grid, and loads, supporting seamless grid-connected and off-grid switching, ensuring uninterrupted power supply to critical equipment 24/7. Technical integration not only enhances system reliability but also improves its adaptability to various complex application scenarios.

(6) Versatility Across Multiple Scenarios
The solar-storage-diesel system is easy to install and can be flexibly transported via vehicles, making it ideal for temporary events, construction sites, field research, and disaster relief situations where stable power supply is crucial. Due to its good mobility and reusability, it also performs well in projects that require frequent location changes.

(7) Policy Support and Market Demand
Under the global transition of the energy power system, the solar-storage-diesel integrated system has gained support from policies and market demand. As countries increasingly prioritize and support clean energy, the solar-storage-diesel integrated system is expected to play a significant role in the future energy sector, becoming the preferred solution for temporary power supply.

In summary, with its flexibility, reliability, environmental friendliness, economic benefits, and technical integration, the solar-storage-diesel integrated system demonstrates broad application prospects and immense development potential in the field of temporary power supply.

4. Technical Solutions for Off-Grid Solar-Storage-Diesel Microgrids

(1) Overall Architecture
The solar-storage-diesel system adopts the design concept of the energy internet, integrating distributed photovoltaic systems and energy storage systems with a hybrid AC/DC three-bus architecture. It incorporates distributed power sources, digital intelligent distribution networks, layered energy storage devices, and short-term grid-connected/off-grid technology. Through a microgrid solar-storage integrated cabinet, the system provides a reliable and stable temporary power supply. Using domestically developed secure wireless data bus and digital twin technology, the system enables digital operation and management of all temporary power points, ensuring a stable, uninterrupted power supply to loads.

Due to the cyclical nature of photovoltaic power generation, the system can store excess solar energy or use the main grid to charge batteries. When photovoltaic generation is insufficient, such as at night or during cloudy weather, the energy storage system releases power to balance building electricity demand, reducing reliance on the main grid. In the event of a grid outage or abnormal grid failure, the energy storage battery can respond in less than 1 millisecond to provide power to critical loads.

When the solar-storage-diesel integrated system is used as a temporary power source at construction sites, it can not only take advantage of peak-valley electricity price differences but also work with distributed photovoltaic power generation to achieve dynamic regulation of building electricity consumption. This regulation not only effectively reduces energy consumption and decreases the frequency of diesel generator use but also allows for participation in electricity market transactions, potentially becoming part of a virtual power plant and generating additional economic benefits.

The solar-storage-diesel system’s microgrid equipment is compact, easy to install, and portable, making it particularly suitable for construction projects that require frequent relocation. Additionally, with a lifespan of up to 25 years for photovoltaic panels, even in short-term temporary power scenarios, these characteristics favor the system’s reuse and redeployment.

(2) Components of the Architecture
The basic configuration of the solar-storage-diesel integrated system includes a microgrid-integrated machine, distributed photovoltaic power generation components, and a microgrid management platform.

Microgrid Integrated Machine
The microgrid-integrated machine has a rated charge/discharge power of 30KW and 60KW, with a long-term overload capability of 110%. Internal components include battery boxes, high-voltage boxes, hybrid inverters, temperature control systems, fire protection systems, distribution units, battery management systems (BMS), microgrid controllers (MEG-core), and energy management systems (EMS).

The system supports both grid-connected and off-grid operation modes, automatically switching to off-grid mode when the main grid is down to provide uninterrupted power supply to users, and automatically switching back to grid-connected mode after recovery. The system’s grid-connected/off-grid switching time is within 1 millisecond, ensuring that user equipment is unaffected and providing safe and reliable power supply.

Operation Management Platform
The platform is divided into a model strategy layer and an edge control layer, enabling intelligent management and monitoring of the entire system.

Secure Wireless Data Bus
Using telecommunications networks and domestically developed secure low-power wireless self-organizing network technology, the microgrid data bus is constructed to achieve secure and confidential data transmission and control.

5. Application Value of Off-Grid Solar-Storage-Diesel Microgrids

(1) Energy Conservation and Emission Reduction
The solar-storage-diesel system reduces reliance on traditional diesel generators, decreases fossil fuel consumption, promotes the use of renewable energy, and thereby reduces carbon and other pollutant emissions, contributing to energy conservation and emission reduction goals.

(2) Cost Efficiency
The solar-storage-diesel system utilizes peak-valley electricity price differences, charging during low-price periods and discharging during peak periods, significantly saving electricity costs. Additionally, reducing diesel generator usage also lowers fuel consumption and maintenance costs.

(3) Reliability and Stability
The system ensures a stable power supply at construction sites, smoothing power output even during grid outages or instability, and ensuring continuous power supply to critical loads.

(4) Flexibility and Adaptability
The equipment’s small size and light weight facilitate transportation and installation, making it suitable for various construction sites and temporary power demand scenarios. The system can also flexibly respond to changes in load demand, quickly adjusting energy supply plans.

(5) Sustainability and Reusability
The photovoltaic components of the solar-storage-diesel system have a lifespan of up to 25 years, allowing the equipment to be reused in multiple projects, improving resource utilization and promoting sustainable development.

(6) Demonstration and Promotion Value
The solar-storage-diesel system aligns with sustainable development and “dual carbon” strategy goals, offering significant demonstration effects and guidance value, helping to enhance corporate social recognition.

6. Expected Benefits of Off-Grid Solar-Storage-Diesel Microgrids

Through the application of the solar-storage-diesel system, enterprises can not only gain economic benefits but also increase income by participating in electricity market transactions and auxiliary services, while reducing environmental pollution, enhancing social responsibility, and improving corporate image. Moreover, various levels of government typically provide policy support and subsidies, further enhancing the project’s economic viability. By conducting a power balance analysis, different solar-storage ratios can be determined. Through economic analysis, the initial investment and levelized cost of energy (LCOE) under different ratios can be calculated, leading to the selection of the optimal solution.

Option 1: Diesel-Only Power Supply
The procurement cost of diesel generators is generally around 2000 RMB/kW, with fuel consumption (L/h) = generator capacity (kW) * 0.25 (L/kW.h), i.e., 0.25L of diesel is consumed per kWh of electricity generated.

Diesel generator operation and maintenance costs include two aspects:

Major Overhaul: After 25,000 hours (3 years) of operation, a major overhaul is required, with three overhauls (10 years) leading to decommissioning of the generator (as further repairs become too costly).
Repair costs: First time: 30% * generator procurement cost; second time: 40% * generator procurement cost; third time: 50% * generator procurement cost.
Maintenance Costs: Every 500 hours, oil and filters need to be replaced.
Comprehensive analysis results in a levelized cost of energy (LCOE) of approximately 0.29 USD/kWh.

Option 2: Solar + Storage + Diesel (Backup Emergency Power)
Option 2 requires configuring 1MW of solar + 1.5MWh of net storage + 200Kw * 2 diesel generators. During the day, 1MW of solar power directly supplies the load, with excess power entering the storage system; at night, the storage system discharges to supply the load. The diesel generator is used only as a backup power source, operating only during continuous rainy days.

This project is located in Africa, where sunlight conditions are excellent, so the solar LCOE is approximately 0.05 USD/kWh. After factoring in the investment cost of the solar power system, the LCOE is approximately 0.1 USD (0.7 RMB/kWh).

Option 3: Solar + Storage + Diesel (Nighttime Power)
Option 3 requires configuring 700kW of solar + 0.5MWh of net storage + 200kW * 2 diesel generators. During the day, 750kW of solar power directly supplies the load, with the photovoltaic system generating 3,000 kWh daily. The storage system is used only for power smoothing control, not for storing electricity for nighttime use. The nighttime load is supplied by the diesel generator, which generates about 1,000 kWh daily.

The energy storage system includes PCS, battery systems, electrical systems, etc. The mainstream battery types are lead-carbon and lithium batteries, with a lifespan of about 10 years. Based on current data, the LCOE for the energy storage system is about 0.4 RMB/kWh. (Note: Costs vary depending on different configurations and operating conditions.) The comprehensive LCOE is approximately 0.13 USD/kWh (0.95 RMB/kWh).

6. Conclusion

As a new comprehensive energy solution, the solar-storage-diesel integrated system combines solar power generation, energy storage, and diesel generators to provide a flexible, efficient, and environmentally friendly power supply method. Its broad application prospects and significant economic benefits make it highly competitive in scenarios such as construction sites, emergency rescue, and temporary events. With continuous technological advancements and increasing market demand, the solar-storage-diesel integrated system is set to become an indispensable component of the future energy sector, contributing to the global green energy transition.